1. Overview
ILFORD industrial X-ray films are available in three types: Y4, Y5, and Y7. They are characterized by high sensitivity, high contrast, high resolution, and fine grain. They can be used directly or in conjunction with lead intensifying screens for exposure to X-rays or γ-rays. They are suitable for non-destructive testing in fields such as electronic components, composite materials, casting and welding, shipbuilding, defense and nuclear industries, and aerospace.
2. Film Classification
Standard/Film Type GB/T19348.1 EN 584.1 ASTM E 1815-06 ISO 11699-1 Y4 C3 C3 Ⅰ C3 Y5 C4 C4 Ⅰ C4 Y7 C5 C5 Ⅱ C5 3. Processing Methods
ILFORD industrial X-ray films are suitable for both manual processing at room temperature and high-temperature machine processing.
Processing Method Applicable Liquid Temperature/℃ Developing Time/min Fixing Time/min Drying/℃ Replenishment ml/m² Manual D-19b 20±0.5 5±1 10 Natural Drying 300 Machine Processing G-30 29±1 1.5-2 2 45-55 4. Product Packaging Specifications
Specification Inner Packaging (sheets/bag) Middle Packaging (bags/box) Outer Packaging (boxes/carton) 356mm×432mm (14 inches×17 inches) 50 100 1 5(50) 3 or 4(100) 305mm×381mm (12 inches×15 inches) 50 1 5 70mm×90M(Y7/Y4) 1 1 100mm×90M(Y7/Y4) 1 1 300mm×400mm(Y7/Y4) 100 1 5 '*Customizable according to user needs'
5. Film Characteristic Curve
Y7 Film Aluminum Characteristic Curve
Y4 Film Aluminum Characteristic Curve
Y7 Film Steel Characteristic Curve
Exposure and Processing Conditions
Shooting Processing X-ray GE E320 Processor Protec PB 0.03mm Applicable Liquid LUCKY G-30 FFD 1m Automatic Processing Time 8 minutes Density 2.5 Developing Temperature 28℃ 6. Film Usage and Storage Conditions
The film needs to be unpacked, loaded, and processed in a darkroom. The safety light should be a dark red safety light, and the distance from the light should be at least 1.2 meters. The film should be stored in a cool, dry place. The optimal storage conditions are a temperature of 10℃~23℃ and a relative humidity of 30%~65%. Strictly avoid storing it in high-temperature, humid, radiation-containing, or chemically gaseous places. It should not be stored in the same room as the processing chemicals, and it should be used within its expiration date.
7. Film Shelf Life
The shelf life of the film stored under compliant conditions is 30 months.