1. Overview
ILFORD industrial radiographic films are available in three types: Y4, Y5, and Y7. They feature high sensitivity, high contrast, high definition, and fine image granularity. They can be used directly or in conjunction with lead intensifying screens for exposure to X-rays or γ-rays. They are suitable for non-destructive testing in fields such as electronic components, composite materials, casting and welding, shipbuilding, national defense and nuclear industry, and aerospace.
2. Film Classification
Standard/Film Type GB/T19348.1 EN 584.1 ASTM E 1815-06 ISO 11699-1 Y4 C3 C3 Ⅰ C3 Y5 C4 C4 Ⅰ C4 Y7 C5 C5 Ⅱ C5 3. Processing Methods
ILFORD industrial radiographic films are suitable for both room temperature manual processing and high-temperature machine processing.
Processing Method Applicable Liquid Temperature/℃ Developing Time/min Fixing Time/min Drying/℃ Replenishment ml/m² Manual D-19b 20±0.5 5±1 10 Natural Drying 300 Machine Processing G-30 29±1 1.5-2 2 45-55 4. Product Packaging Specifications
Specification Inner Packaging (sheets/bag) Middle Packaging (bags/box) Outer Packaging (boxes/carton) 356mm×432mm (14 inches × 17 inches) 50 100 1 5(50) 3 or 4(100) 305mm×381mm (12 inches × 15 inches) 50 1 5 70mm×90M(Y7/Y4) 1 1 100mm×90M(Y7/Y4) 1 1 300mm×400mm(Y7/Y4) 100 1 5 *Customizable according to user needs
5. Film Characteristic Curves
Y7 Film Aluminum Characteristic Curve
Y4 Film Aluminum Characteristic Curve
Y7 Film Steel Characteristic Curve
Exposure and Processing Conditions
Shooting Processing X-ray GE E320 Processor Protec PB 0.03mm Applicable Liquid LUCKY G-30 FFD 1m Automatic Processing Time 8 minutes Density 2.5 Developing Temperature 28℃ 6. Film Usage and Storage Conditions
Films should be unpacked, loaded, and processed in a darkroom. The safety light should be a dark red safety light, at least 1.2 meters away. Films should be stored in a cool, dry place. The optimum storage conditions are a temperature of 10℃~23℃ and a relative humidity of 30%~65%. Strictly avoid storing in high-temperature, humid, radioactive, or chemically gaseous environments. They should not be stored in the same room as processing chemicals and should be used within their expiration date.
7. Film Shelf Life
The shelf life of films stored under compliant conditions is 30 months.